ATS

Mã SP :
Đánh giá của bạn về sản phẩm này
Overview Vietnam Asia :ATS is a system of automatic power switch , which takes effect when the electricity generators automatically start up and shut power to the load . When grid power is restored [...]
Xem thêm

Tổng quan sản phẩm :

Overview Vietnam Asia :
ATS is a system of automatic power switch , which takes effect when the electricity generators automatically start up and shut power to the load . When grid power is restored automatically switch the system back to the source and transmitter automatically turn off .
* In addition, the cabinet automatically switch sources ( ATS ) is likely to protect the function and Electric Power Grid are incidents such as phase loss , loss of neutral , low pressure ( custom ) switching times can adjustment .

II . Specification ATS pick : Closets are often chosen with the following main elements :

* Consistent with engine capacity
* Suitable for tropical environments , coastal salt air contamination and islands .
* Ensure the requirements for control

III . Functional operation of ATS :

* Automatically send a signal when the machine boots : complete loss of power , loss of phase grid , the grid voltage is lower than the allowable value ( this value can be adjusted ) . Time to switch to generator power is 5-30 seconds
* When power restored , the ATS load immediately transfer power to the grid . Automatic machine running cool off after 1 -2 minutes .
* Ability to operate automatically or employees.
* Adjustable switching time .
* Is indicator system .

IV . Some warning lights and buttons common functions :

* Mains indicator light signals Mesh Available within the allowable range .
* Mains On Load Indicator light signals are supplied to the Electricity Grid to load .
* Available Indicators Generator Electric light signal value allowed .
* On the Load Generator warning light signal light Electric is providing for the load .
* Delay start generator ( Delay Start ) , this time custom .
* Delay restoration grid back ( Delay On Restoration ) , this time custom .
* Postponed grid close to the load ( Delay On Transfer ) , this time custom .
* Postponed to play electric load ( Warm Up ) , this time custom .
* Runs cooling ( Cool Down ) , this time custom .
* Lets try to boot the machine up to 03 times .
* Low battery charger Automatic ( Battery Charger ) pulse regulatory principles .
* The ATS allows users to choose or grid power electronics supply the load when needed through Manual Switch switches .

V. Assemble and install :

* ATS has simple structure , so can assemble in or out of the country . ATS Quality depends on the switchgear .
* G7 equipment and components assembled in Vietnam . Often used Contactor or circuit breaker MCCB 3 phase grid depending on engine capacity .
ATS principle diagram .
ATS system automatically transfers power between the main source and redundant power
A . The ATS control : We can assemble with lots of options :
1 - Digital Electronic Circuits of the EAC , secure and accurate , please click here
Catalog - EAC tariff circuit ATS - ATS , please Quotation button - Manual to download
2 - The controller integrated : as DATAKOM , Osung , Hyundai .....
3 - PLC : LOGO , ZEN , plus ..... please 1.900.000đ compared to the price list (including auxiliary supplies more )
4 - Circuit relay ( suitable for semi-automated system , reducing costs )
B . Section switching dynamics : can use MC - Contactor , ACB Air Circuit , ATS - breaker switches ( Osung , Socomec ) , .........
We wish to cooperate !
Diagram reference ATS play installation with EAC circuit :


PANEL ABOUT ATS - ATS

I.Tong with :
ATS is a system of automatic power switch , which takes effect when the electricity generator starts automatically and plays for load generators . When power is restored the system automatically turn power back on and automatically turn off the transmitter.
- Also, from Automatic switch ( ATS ) has protective function when Power Grid malfunction such as phase loss , loss of neutral , low pressure ( custom ) switching time can be adjusted .

II . Specification ATS pick :
- Consistent with engine capacity
- To ensure that the requirements of the control features

III . Functional operation of ATS :
- Protects generator , because the time delay between the cut and play MC MC generator power generator should be safety
- Load protection , due to the power grid is checked , if the power grid to ensure new plays for download
- Automatically send the signal to start the machine : complete loss of power , loss of phase , or lower voltage value allowed ( this value can be adjusted ) .
- Time to switch to generator power options , but > 5s , to ensure stable electricity generator
- When power restored , the ATS transfer load to the grid resources . Automatic machine running cool off after 1-15 minutes .
- Ability to operate automatically or employees.
- Adjust the switching period .
- Is the indicator system .
Specifically:

1 . Displays :

a.Mat cabinet :
- Lights MAIN : power indicator light
- GEN light : lights generators
- Lamp ON MAIN LOAD : grid level are reported for download
- Lamp ON GENETIC LOAD : power generators are reported for download
b.Trong cabinet :
- Lights GOOD : power indicator light located in the allowable range
- Lights ERROR : power indicator light does not reach
Lights ....... and some other

2 . Switch controls :

- Switching MAIN - AUTO - GEN ( ATS mode )
MAIN : closed grid for load conditions
GEN : Generator for load conditions
AUTO : run fully automatically
- Switching AUTO - OFF - TEST ( generator mode )
TEST : run electricity generators regardless of how
AUTO : run fully automatically
OFF : turn off the generator completely

3 . Parameters can be adjusted by the user :

a. ATS section :
- Low voltage protection threshold of power ( Voltage Sensing Main )
- Delay time to test grid was completely stable when the power comes back ( Retranfer )
- Delay time for load power play ( Transfer )
- Standby time heating generator , electric generator to close the stable generators for download ( Warm up )
- Standby time generator and cooling off ( Cool Down )

b . Part AUTO START MODULE (optional )
- Time delay start generators , generators or heating ( Delay start - Preheat )
- Select the startup generator ( Select starting times)
- Boot Time ( Start )
- Vacation time between the start time ( Idle )
- Time to stop the machine level signal ( Stop - Stop the kind of output)
                                                                                                                 Author : Nguyen Thuong